- Check and where
necessary adjust gas consumption
- Check
and where necessary adjust gas pressures at
minimum,
ignition, hot water maximum, and heating
maximum
- Check
and where necessary adjust heating system
pressure
- Check
and where necessary adjust expansion vessel
pre-charge pressure
- Test safety
devices
-
Function test controls
-
Inspect for leaks
- Where
required clean heat exchanger, burner, air intake
grills,
injectors, coals, ceramics, vermiculite granules*, and
catchment space
- Where required
analyse flue gasses for correct combustion
- Check ventilation
is adequate and clear
- Test flue with a
smoke bomb where required
- Test flue
operation for clearance of products of combustion
where required
-
Re-secure closure plates
- Advise of any
repairs if required
*If filtration of sand/vermiculite granules/debris
is required an additional £13 will be charged.
In the event of any appliances being dangerous or potentially
dangerous, and a remedy cannot be immediately effected, the
appliance will be made
safe (with your permission) and a warning
notice issued. A charge may
be made for this
depending on the time taken and any parts used.
|